Reference values for CertiFiber Pro

CertiFiber Pro® 2015-04-01

If your reference values fail to meet the expected power stated below, you should inspect the output ports as well as your test reference cords using a video microscope such as the FI-1000; an optional probe for your CertiFiber Pro.

Reference values for CertiFiber Pro

Where -24 dBm is better than -25 dBm.

If your reference values are within expectation, your test reference cords could still be poor. Verifying your test reference cords is a separate procedure. For SC, LC, ST and FC duplex links, use the RUN WIZARD in the CertiFiber Pro. This will walk you through the reference procedure including the all-important step of verifying the test reference cords, and it also saves a record of the TRC verification in your test results. The following articles also describe this TRC check process:

Note: No TRC Verification possible for this setup